Clean Pad Drop Error Abnormality
Pin-Jet helped the customer determine the reason for the abnormality
The customer gave the feedback that the clean pad would not fall after the vacuum in the NEST was broken; after confirmation by Pin-Jet, it was found that there was inverted round corners inside the NEST, but the clean pad had a right-angle exterior, which caused interference.
Problem Description
✔ Abnormal problem: Solve the problem of the clean pad getting stuck in the clamp and unable to be lowered when trying to lower it for cleaning
✔ Package type: BGA
✔ Target: Solve abnormal problems
Problem Confirmation
Clean Pad | Clamp | |
---|---|---|
Entity |
![]() |
![]() ※ The Clean Pad originally had a right-angle design
and therefore interfered with the Clamp R angle; |
Actual size | 15.57 x 15.57mm | 15.71 x 15.72mm |
Conclusion | The Clean Pad Lid is a right angle and the Clamp Lid is a R angle; they do not match and therefore when lowered for cleaning, the clean pad gets stuck in the clamp and cannot be lowered. It is recommended to change the design of the Clean Pad Lid to improve the current problem. |
Implementation Verification
Before Modification | After Modification | |
---|---|---|
Entity |
![]() |
![]() |
Verification conclusion | Before modification, the clean pad got stuck in the clamp and cannot be lowered when trying to lower it for cleaning. | After modification, the Clean Pad Lid was changed to rounded corners, and the samples all worked normally after verifying the modification. |
Conclusion:
Before modification, the clean pad got stuck in the clamp and could not be lowered for cleaning.
After modification, the Clean Pad Lid was changed to rounded corners, and the samples all worked normally after verifying the modification.
-
Product ICI Fail & Pin Low Life Time
2024/01/11 Product ICI Fail & Pin Low Life Time Although the pin tip was not blunted, but when analyzed through related instruments such as X-ray and FDR, it was discovered that the gold plating layer at the end of the pin had peeled off, which could easily cause ICI Fail.
-
Socket SB21512 Fail Issue
2024/01/11 Socket SB21512 Fail Issue 3ea socket had SB21512 Fail during NPI engineering, and the true cause could not be found. Pin-Jet helped discover that the customer’s socket had wetting; however, after cleaned, reinstalled and tested, the abnormality still occurred. We cross-checked with another Corr IC and the manual test passed. It was confirmed that the read value of this Corr IC that had this abnormality easily was higher compared to the Corr IC that passed.
-
SLT Test Low Yield
2024/01/11 SLT Test Low Yield The customer gave the feedback that the Pin Life time was approximately 70K; after confirmation by Pin-Jet, it was discovered that when the same PCB & socket was reassembled multiple times, the test results of each manual test were different. After investigation, it was found that the PCB pad was punctured and necessary to be replaced.
-
SB5XXX LDO Item Test Fail
2024/01/11 SB5XXX LDO Item Test Fail The customer gave the feedback that the LDO item failed easily; after manual testing, it was confirmed that it passed stably with no LDO item fails. After Pin-Jet aligned with the customer, problems with the LDO item occurred easily when contact mool was used; after confirming, it was found that the reason was because the customer had insufficient clamp force, which caused poor contact.